Abstract

This paper presents a highly sensitive closed loop enclosed split ring biosensor operating in microwave frequencies for measuring blood glucose levels in the human body. The proposed microwave glucose biosensor, working on the principle of high field confinement and concentrated energy, has been tested using both in-vitro and in-vivo methods. This principle allows the sensor to concentrate energy at the surface which results in improved accuracy of measurements. For in-vitro measurements, the biosensor has been tested using de-ionized water glucose solutions of different concentrations. The miniaturized micrometer scale biosensor is fabricated over a thin Si-substrate using photolithographic technique. The biosensor has been designed in a way to operate at desired microwave frequencies. Highly confined fields and concentrated energy inside the closed loop line containing the split ring resonators are responsible for the sensitivity enhancement. This new biosensor has obtained a high sensitivity of 82 MHz/mgmL−1 within the clinical diabetic range during in-vivo testing over the human body. In addition, the subjects (undergoing experiments) steady state has been continuously monitored throughout the experiment which helps in improving the accuracy of the results. The proposed biosensor has further obtained a low detection limit of <0.05 wt.% and can be useful for continuous non-invasive blood glucose monitoring.

Highlights

  • For painless treatment and to measure the blood glucose levels accurately, a new methodology for non-invasive blood glucose measurements is a requirement

  • In13–15, research groups have been actively involved in finding a suitable methodology and developing glucose sensing system at microwave and millimeter wave frequencies

  • Our research proposed a new methodology to measure blood glucose levels in the human body successfully in millimeter wave frequencies[19] and the technique is under development for further refinement

Read more

Summary

Enclosed Split Ring Biosensor

Abhishek Kandwal[1], Tobore Igbe[1], Jingzhen Li1,Yuhang Liu[1], Sinan Li1, Louis W.Y. This paper presents a highly sensitive closed loop enclosed split ring biosensor operating in microwave frequencies for measuring blood glucose levels in the human body. To overcome the above-mentioned issues, the proposed blood glucose measurements were conducted at microwave frequencies with the help of a closed loop enclosed split ring based sensor. This biosensor has effectively concentrated energy on the surface by generating highly confined fields. The proposed closed loop split ring glucose sensor has combined the features of split ring resonators and the concept of highly concentrated energies to successfully achieve high sensitivity and low detection limit in both in-vitro and in-vivo measurements. A noticeable change of 5 dB in the return loss can be seen

Experimental Measurements in Controlled Environment
Our work
Conclusions
Author contributions
Findings
Additional information
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call