Abstract
A new sensitive voltammetric sensor was developed for electrochemical determination of captopril (CAP) at a modified multiwall carbon nanotubes paste electrode with p-aminophenol (p-APMCNTPE). The result showed that p-APMCNTPE has high electrocatalytic activity for captopril oxidation at pH 6.0. Cyclic voltammetry (CV), double potential-step chronoamperometry and square wave voltammetric (SWV) were used to investigate the suitability of p-aminophenol into carbon nanotubes paste matrix as mediator for the electrocatalytic oxidation of CAP in aqueous solution. It has been found that under the optimum condition (pH 6.0), the oxidation of captopril occurred at a potential ca. 200 mV at p-APMCNTPE. The kinetic parameters, such as electron transfer coefficient and catalytic reaction rate constant, were also determined using the electrochemical approaches. Under optimized conditions, the electrocatalytic oxidation peak current of captopril showed two linear dynamic ranges, 5.0 × 10-8 to 5.0 × 10-7 and 5.0 × 10-7 to 5.0 × 10-5 mol L-1 using SWV. The limit of detection was 2.0 × 10-8 mol L-1. Finally, the modified electrode was also examined as a selective, simple and precise new electrochemical sensor for the determination of captopril in real samples, such as pharmaceutical preparation and urine.
Highlights
Captopril, (2S)-1-[(2S)-3-mercapto-2-methyl propanoyl] pyrrolidine-2-carboxylic acid, is a specific inhibitor of the angiotensine converting enzyme which is widely used in the treatment of hypertension.[1,2,3] Captopril is metabolized to disulfide conjugates with otherHighly Selective and Sensitive Voltammetric Sensor for Captopril DeterminationJ
In continuation of our studies concerning the preparation of chemically modified electrodes,[35,43,44,45] we describe the use of p-aminophenol modified multiwall carbon nanotubes as a suitable and sensitive sensor for the electrooxidation of captopril in aqueous media
The electrochemical properties of the modified electrode were studied by cyclic voltammetry in the buffer solution
Summary
Captopril, (2S)-1-[(2S)-3-mercapto-2-methyl propanoyl] pyrrolidine-2-carboxylic acid, is a specific inhibitor of the angiotensine converting enzyme which is widely used in the treatment of hypertension.[1,2,3] Captopril is metabolized to disulfide conjugates with otherHighly Selective and Sensitive Voltammetric Sensor for Captopril DeterminationJ. Captopril, (2S)-1-[(2S)-3-mercapto-2-methyl propanoyl] pyrrolidine-2-carboxylic acid, is a specific inhibitor of the angiotensine converting enzyme which is widely used in the treatment of hypertension.[1,2,3] Captopril is metabolized to disulfide conjugates with other. Selective and Sensitive Voltammetric Sensor for Captopril Determination.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.