Abstract

A new type of rotating anticathode X-ray generator has been developed, in which the electron beam irradiates the inner surface of a U-shaped anticathode (Cu). A high-flux electron beam is focused on the inner surface by optimizing the shape of the bending magnet. The power of the electron beam can be increased to the point at which the irradiated part of the inner surface is melted, because a strong centrifugal force fixes the melted part on the inner surface. When the irradiated part is melted, a large amount of energy is stored as the heat of fusion, resulting in emission of X-rays 4.3 times more brilliant than can be attained by a conventional rotating anticathode. Oscillating translation of the irradiated position on the inner surface during use is expected to be very advantageous for extending the target life. A carbon film coating on the inner surface is considered to suppress evaporation of the target metal and will be an important technique in further realization of highly bright X-ray generation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.