Abstract
Active Radar Calibrators (ARC), also called calibration transponders, are often used as reference targets for absolute radiometric calibration of radar systems due to their large achievable Radar Cross-Section (RCS). However, before using a transponder as a reference target, the hardware itself has to be calibrated. A novel method, called the three-transponder method, was proposed some years ago and allows for RCS calibration of digital transponders without using any RCS targets as reference. In this paper, this technique is further refined and applied to a setup utilizing only one digital transponder. The accurate measurement design is described and a novel, elaborated data processing scheme is developed to minimize remaining noise and clutter effects in the data. A comprehensive error analysis is presented in the second part of this paper.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.