Abstract

Forward-masked psychophysical tuning curves (PTCs) were obtained for 1000-Hz probe tones at multiple probe levels from one ear of 26 normal-hearing listeners and from 24 ears of 21 hearing-impaired listeners with cochlear hearing loss. Comparisons between normal-hearing and hearing-impaired PTCs were made at equivalent masker levels near the tips of PTCs. Comparisons were also made of PTC characteristics obtained by fitting each PTC with three straight-line segments using least-squares fitting procedures. Abnormal frequency resolution was revealed only as abnormal downward spread of masking. The low-frequency slopes of PTCs from hearing-impaired listeners were not different from those of normal-hearing listeners. That is, hearing-impaired listeners did not demonstrate abnormal upward spread of masking when equivalent masker levels were compared. Ten hearing-impaired ears demonstrated abnormally broad PTCs, due exclusively to reduced high-frequency slopes in their PTCs. This abnormal downward spread of masking was observed only in listeners with hearing losses greater than 40 dB HL. From these results, it would appear that some, but not all, cochlear hearing losses greater than 40dB HL influence the sharp tuning capabilities usually associated with outer hair cell function.