Abstract
Objective: To investigate the value of high-frame rate vector flow imaging technique (V flow) in evaluating the hemodynamic changes of carotid stenosis caused by atherosclerotic plaques.Methods and Materials: In this prospective study, patients with stenosis rate (diameter) ≥30% caused by carotid atherosclerotic plaques were included. Degrees of carotid stenosis were graded according to North American Symptomatic Carotid Endarterectomy Trial criteria: moderate (30–69%) or severe (70–99%). Mindray Resona 7s ultrasound machine with a linear array transducer (3–11 MHz) was used for ultrasound examinations. The mean WSS value of carotid arteries was measured at the proximal, narrowest region and distal of carotid stenosis. The mean WSS values were correlated with peak systolic velocity (PSV) measured by color Doppler flow imaging and stenosis degree detected by digital subtraction angiography (DSA). The vector arrows and flow streamline detected by V flow dynamic imaging were analyzed. Imaging findings of DSA in carotid arteries were used as the gold standard.Results: Finally, 51 patients were included. V flow measurements were performed successfully in 17 patients (100%) with moderate-grade stenosis and in 30 patients (88.2%) with severe-grade stenosis. Dynamic V flow imaging showed yellow or red vectors at the stenotic segment, indicating fast speed blood flow (up to 260.92 cm/s). Changes of streamlines were detected in the stenotic segment. The mean WSS value measured at the narrowest region of the carotid artery had a moderately positive correlation with stenosis degree (r = 0.58, P < 0.05) and PSV value (r = 0.54, P < 0.05), respectively. Significant difference was detected in mean WSS value at the narrowest region of the carotid artery between severe carotid stenosis (1.47 ± 0.97 Pa) and moderate carotid stenosis (0.96 ± 0.44 Pa) (P < 0.05).Conclusion: The hemodynamic changes detected by V flow of the carotid stenosis might be a potential non-invasive imaging tool for assessing the degree of carotid stenosis.
Highlights
Carotid stenosis caused by atherosclerotic plaque is the main cause of ischemic stroke and has a high incidence rate among people 65 years or older [1, 2]
The hemodynamic changes detected by vector flow imaging technique (V flow) of the carotid stenosis might be a potential non-invasive imaging tool for assessing the degree of carotid stenosis
The aim of our study is to investigate the value of V flow in evaluating the hemodynamic changes of carotid stenosis caused by atherosclerotic plaques
Summary
Carotid stenosis caused by atherosclerotic plaque is the main cause of ischemic stroke and has a high incidence rate among people 65 years or older [1, 2]. Preoperative diagnosis of carotid artery stenosis is important for the further choice of treatment as a reasonable treatment method should be selected according to the patient’s carotid stenosis degree. Asymptomatic patients with severe carotid artery stenosis or patients with symptomatic moderate carotid artery stenosis require surgical treatment [3, 4]. Hemodynamic change, the functional evaluation, is one of the crucial factors in evaluating carotid stenosis. Combined functional evaluation such as hemodynamic changes (including the blood flow velocity, flow direction, flow pattern, and blood viscosity) of the carotid artery may provide additional information for the diagnosis and decision-making process of the carotid stenosis
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.