Abstract

Abstract A boiling experiment was conducted to acquire a three-dimensional void fraction distribution in a rod bundle with part length rods. The test section was a 5 × 5 heated rod bundle that partially simulated a BWR rod bundle, and three PLRs were arranged together in the corner. The heated length of the full-length rod was 3.71 m, which is equal in length to an actual fuel rod in BWRs, whereas the heated length of the PLR was 1.85 m. The rod bundle exhibited an axially and radially uniform heat flux. Further, the local void fraction was quantified by normalizing the intensities in the CT images of the boiling two-phase flow with those obtained under the liquid-phase and gas-phase conditions. The cross-sectional void fraction distribution was acquired at six height levels. The experimental results exhibited the void distribution around PLRs with respect to a wide range of flow conditions, inlet temperatures, inlet flow rates, bundle thermal powers, and system pressures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.