Abstract

A new boost half bridge (BHB) converter is presented. It is composed of additional switch, diode and coupled winding to boost inductor of BHB converter. Using the transferring of boost inductor current to coupled winding in a short period, the cancellation of zero voltage switching (ZVS) current, which always occurs in convention one, is prevented. Therefore, the ZVS operation is easily achieved by leakage inductor current of transformer. Furthermore, since negatively build-up leakage inductor current of boost winding helps the ZVS operation throughout full load range, the excellent ZVS operation and high efficiency is achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.