Abstract

Existing current sensors suffer from insufficient measurement bandwidth or large insertion area to continuously monitor the switching transient current of wide-bandgap devices. A combinational Rogowski coil concept is proposed here, where the self-integrating region of a shielded Rogowski coil is combined with its differentiating region. The overall measurement bandwidth is effectively extended by the self-integrating region. The design methodology for the shielded Rogowski coil, especially the parasitic elements and error analysis, is discussed. Finally, a prototype is demonstrated with a sensitivity is 5.0 mΩ and a bandwidth of 200 MHz. The measurement in a SiC power module double pulse shows it can faithfully capture the transient current while introducing little interference.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call