Abstract
The ion linear accelerators stable operation essentially depends on the ion injector. To ensure maximum capture of the ion beam injected into the accelerating structure, the injector must be able to adjust the beam parameters. The paper describes the developed new injector power supply system, built on modern assemblies, which allows smoothly changing the modulator pulse duration in the range of 300…2000 µs. The analysis was carried out and the shortcomings of the previous systems were eliminated. The expected increase in the accelerated ion beam current is 15…20%. Related results include a decrease in the parasitic load capacitances of pulsed devices, a reduction in size, and the rejection of high-voltage isolation transformers, which increases the reliability of the accelerator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.