Abstract

In the present study, a high-throughput homogenous liquid-liquid extraction method was developed for fast sample preparation of multiple phenolic compounds in propolis. This method was proposed based on cooling samples array in subzero temperature to induce phase separation of ACN-H2O extractant. Due to the high-throughput ability, optimization of extraction parameters was rapidly achieved by using a 5 × 4 × 3 samples array. In addition, multiple arrays were investigated for evaluating the analytical performance of the high-throughput method, which indicated that limits of detection and quantification were ranged from 0.04 to 0.35 µg/mL and 0.12 to 1.05 µg/mL, respectively. Recoveries and precisions in inter-day high-throughput studies were in the range of 90.55–105.50% and 2.58–4.30%, respectively. Comparing with the conventional liquid extraction method, this ecofriendly high-throughput method presented remarkable advantages in reducing sample and chemical consumption, as well as saving labor and time cost. The proposed method might provide a valuable strategy for the design of high-throughput extraction procedures.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call