Abstract
BackgroundRed raspberry fruit color is a key driver of consumer preference and a major target of breeding programs worldwide. Screening for fruit color typically involves the determination of anthocyanin content and/or the assessment of color through a colorimeter. However, both procedures are time-consuming when the analyses involve hundreds or thousands of samples. The objectives of this study were to develop a high-throughput method for red raspberry puree color measurement and to test the correlations between color parameters and total anthocyanin content. Color coordinates were collected with a colorimeter on 126 puree samples contained in Petri dishes and with the Tomato Analyzer Color Test (TACT) module to assess the same samples prepared in Petri dishes and in 96-well plates. An additional 425 samples were analyzed using only 96-well plates. Total anthocyanins were extracted from all 551 samples.ResultsRegression models for L*, a*, b* measured with the colorimeter and TACT using Petri dishes were all significant (p < 0.001), but very consistent only for L* (R2 = 0.94). Significant (p < 0.001) and very consistent regressions (R2 = 0.94 for L* and b*, R2 = 0.93 for a*) were obtained for color parameters measured with TACT using Petri dishes and TACT using plates. Of the color parameters measured with the colorimeter, only L*, a*/b*, and hue significantly correlated with total anthocyanins (p < 0.05), but, except for L* (R = − 0.79), the correlations were weak (R = − 0.23 for a*/b* and R = 0.22 for hue). Conversely, all correlations with total anthocyanins and color parameters measured with TACT were significant (p < 0.001) and moderately strong (e.g., R = − 0.69 for L* and R = 0.55 for a*/b*). These values were indicative of darker colors as total anthocyanin content increased.ConclusionsWhile the colorimeter and TACT-based methods were not fully interchangeable, TACT better captured color differences among raspberry genotypes than the colorimeter. The correlations between color parameters measured with TACT and total anthocyanins were not strong enough to develop prediction models, yet the use of TACT with 96-well plates instead of Petri dishes would enable the high-throughput measurement of red raspberry puree color.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.