Abstract

A high-throughput assay was developed to detect soybean lipoxygenase 1 (LOX-1) using a multilabel plate reader. The assay was also adapted to a single cell fluorometer. Fluorescein is degraded by linoleic hydroperoxide produced from soybean lipoxygenase and linoleic acid. The decrease in fluorescence is measured over time, and the area-under-the-curve (AUC) is used to quantify the LOX-1 content of soybean extract. A dose-dependent response is seen with varied dilutions of pure LOX enzyme or soybean extracts. Percent recovery was between 97% and 108%, and relative standard deviation was 4.3%. Advantages of the assay include the reduced preparation time of samples and reduced use of reagents in the high-throughput assay. Multiple samples can be measured in a single run with a multilabel plate reader.