Abstract

In kraft paper mills, supersonic steam jets are used to remove deposits that build up on the heat exchanger tubes in the recovery boiler. In this study, the fracture toughness KC and work of fracture, WF, of simulated boiler deposits were measured at temperatures up to 500 °C to determine the optimal conditions for deposit removal. The model deposits experienced an important brittle to ductile transition at ~450 °C. Above this temperature, ductile deposits required lower peak force, but four times more energy to fracture when compared to those tested at lower temperatures. The transition was clear in scanning electron micrographs of the fracture surfaces. The findings have significant implications for mills wishing to optimize sootblower performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.