Abstract
As an initial part of development of Pt-Mo alloy thermocouples for applying them to in-core outlet-gas temperature measurement in a very high temperature gas-cooled reactor (VHTR), bare element wires of Pt-5%Mo/Pt-0.1%Mo thermocouple were tested in a high-temperature Ar atmosphere of 1,000∼1,400°C for 30 h and in vacuum at 1,200°C for 3,000 h, and stabilities of their electromotive force and mechanical strength were examined as well as observations of their metallographical changes. In the high-temperature Ar atmosphere, selective reaction of Mo with impurity gases contained in the Ar took place very actively in the element of Pt-5%Mo, and its mechanical strength decreased considerably with losing its luster. In the high-temperature vacuum, however, the element wires showed very stable electrical, mechanical and metallographical characteristics for a long-term of 3,000 h. This suggested the importance of clean environmental atmosphere around the element wires. Based on the result, Ta-sheathed thermocouple...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.