Abstract

From our research and development in hard x-ray lithography, we have found that our conventional leadscrew driven scanner stages do not provide adequate scan speed or travel. These considerations have led us to develop a scanning system based on a long stroke hydraulic drive with 635 mm of travel and closed loop feedback to position the stage to better than 100 micrometers. The control of the device is through a PC with a custom LabView interface coupled to simple x-ray beam diagnostics. This configuration allows us to set a variety of scan parameters, including target dose, scan range, scan rates, and dose rate. Results from our prototype system at beamline X-27B are described as well as progress on a production version for the X-14B beamline.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.