Abstract
The high speed enrichment of benzoylurea insecticides (BUs) in complex matrices is an essential and challenging step. The present study focuses on the synthesis of a hierarchical pore nitrogen-doped carbon material for magnetic solid phase extraction (MSPE) of BUs. This material was prepared through the carbonization of a composite material ZIF-67@MCA which assembly with hydrogen-bonded organic frameworks (melamine-cyanurate, MCA) and zeolitic imidazolate framework (ZIF-67) at room temperature. The optimal adsorption effect is achieved when the mass ratio of ZIF-67 to MCA is 1/3, and the carbonization was performed at 600 °C, the such obtained carbon material was denoted as 1/3ZIF-67@MCA-DCs-600. The material was characterized with various physical methods including X-ray diffractometry (XRD), Fourier transform infrared spectrometry (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), Brunauer–Emmett–Teller (BET), vibrating sample magnetometer (VSM), water contact angle measurement, Raman spectrometry. 1/3ZIF-67@MCA-DCs-600 exhibits a macro-mesoporous 3D structure with a high degree of nitrogen doping and relatively large specific surface area, making it suitable for magnetic solid phase extraction (MSPE). The adsorption of BUs with concentration of 100 ng mL-1 can reach equilibrium within 5 s. The interaction between BUs and the adsorbent, facilitated by π-π stacking, hydrophobic interactions, hydrogen bonding forces, as well as the material's porosity, enables efficient extraction recoveries ranging from 45 % to 92 %. The enrichment of BUs was achieved through the establishment of an MSPE method under optimized conditions, which was further coupled with high performance liquid chromatography (HPLC) for the determination of the four BUs. The linear range spans from 5 ng ml-1 to 1000 ng ml-1 with the correlation coefficient (R2) of ≥ 0.99, Meanwhile, the detection limit for these four BUs falls within the range of 0.01 to 0.10 ng ml-1. The material exhibits good reusability and can be reused for at least 5 cycles. Inter day and intra-day precision ranges from 2.1-7.9 % and 1.0-5.4 %, respectively. The method demonstrates a high level of reliability in practical applications for the determination of BUs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.