Abstract

Failures of welded main steam pipes in power station plants are related to cracks forming and propagating in the fine-grained zone, so called heat-affected zone (HAZ). Experience shows that Type IV cracks are indeed some of the most common causes of creep failure for low-alloy ferritic steel pipes and headers in power stations. Typically, crack damage will be characterised by high strain rates in the HAZ and local grain boundary separation, which leads to crack growth. In this paper, the high sensitivity technique for detecting creep damage (Type IV cracking), based on focused ultrasound was implemented. Signal processing algorithms were proposed that enable associating the properties of backscattered signals to the internal characteristics of the metal structure. As the result, the boundaries of the parent metal, HAZ and weld metal in an ultrasonic image can be indicated. The approach was validated on the samples exposed to different levels of creep damage and verified with metallographic analysis. It demonstrated that technique allowed detecting clouds of early stage creep damage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.