Abstract
A high sensitivity pressure sensor design without a polymer transducer is demonstrated in this paper. The sensor uses a thin metal diaphragm as a pressure transducer instead of a polymer. The sensor is tested to a maximum pressure of 100 psi and has a sensitivity of 0.0115 nm/psi, which matches the calculated sensitivity of 0.0127 nm/psi. The sensor is provides accurate measurement of the pressure and shows good repeatability in its readings. The sensor is also tested at the flow loop of the University of Tulsa, and shows a good match with the pressure readings of the flow loop.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.