Abstract

This study aims to identify sources of per- and polyfluoroalkyl substances (PFAS) to wastewater treatment plants (WWTPs) and reveals previously undescribed variability in daily PFAS concentrations by measuring their occurrence in WWTP influent each hour over the course of a week. ∑50PFAS concentrations ranged between 89 ± 38 on Monday and 173 ± 110 ng L-1 on Friday, where perfluoroalkyl carboxylic acids (PFCAs), disubstituted phosphate esters (diPAPs), and perfluoroalkyl sulfonic acids (PFSAs) contributed the largest proportion to overall weekly concentrations 37%, 30%, and 17% respectively. Simultaneous pulse events of perfluorooctanesulfonic acid (PFOS; 400 ng L-1) and perfluoroheptanesulfonic acid (PFHpS; 18 ng L-1) indicate significant industrial or commercial waste discharge that persists for up to 3 h. The minimum number of hourly grab samples required to detect variation of PFOS and PFHpS concentrations are 7 and 9 samples respectively, indicating a high degree of variability in PFAS concentrations between days. Overall, the risk of sampling bias from grab samples is high given the variability in PFAS concentrations and more frequent sampling campaigns must be balanced against the cost of analysis carefully to avoid the mischaracterisation of mass flux to receiving surface waters.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call