Abstract

This study proposes a high-resolution optical fiber Fabry–Perot (FP) temperature sensor and it is based on an exposed-core microstructured optical fiber (ECF) coated by a ultraviolet curing polymer adhesive. Then, a small piece of multimode fiber (MMF) with large core diameter is spliced in front of ECF to expand the input light beam, and the parallel polymer/air double-cavity FP in such single-mode fiber (SMF)-MMF-ECF-SMF structure is constructed. Additionally, by employing a mobilized demodulation module, the interference signal is analyzed by phase demodulation method. The experimental results show that the temperature sensitivity of the sensor is 30.8 ℃−1 and the resolution is up to 1.6 × 10−4 ℃ in a range of 20 ℃–50 ℃, which can achieve high resolution temperature measurement. Furthermore, to alleviate the wavelength uncertainty of the demodulation device, a double-cavity self-reference differential phase modulation method is explored in the proposed parallel double-cavity FP. It shows that the stability could be improved to five times when system temperature is unstable, which offers an alternative method to further improve the temperature sensing resolution.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call