Abstract

In this paper, an inclinometer based on a vertical pendulum and a fiber Bragg grating Fabry–Perot cavity (FBG-FP) is proposed. A low-damping rotation structure is used to reduce the mechanical frictions of the pendulum system and induce a wavelength shift of FBG-FPs. We find that the sensitivity can be maximized by optimizing the parameters of the inclinometer. Using a high-resolution demodulation system, a sensitivity of 179.9 pm/(°), and a resolution better than 0.02″ can be achieved. Experiments also show that the proposed inclinometer has good linearity and repeatability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.