Abstract

We report a case of a 48-year-old woman with a sudden-onset unexplained conductive unilateral hearing loss. There was no improvement after a trial with systemic corticosteroids. On otomicroscopy, the right tympanic membrane showed an abnormal outline of the malleus handle. Pneumatic otoscopy revealed excessive movement of the umbo compared with the lateral process. Audiometric testing showed a conductive hearing loss in the right ear, with an average pure-tone audiometry of air conduction of 40 dB and a maximum air-bone gap of 45 dB at 500 Hz. Tuning fork tests confirmed conductive hearing loss. Tympanometry showed increased compliance in the right ear and an absent ipsilateral stapedial reflex in response to a broad-band stimulus. High resolution computed tomography (CT) imaging of the temporal bone was performed by a high-definition CT system (Discovery CT750 HD®, GE, Hounslow, England). MIP (Maximum Intensity Projection) coronal ultrafine (around 0.1 mm) reconstructions of the malleus revealed a small non-displaced isolated fracture of the malleus handle (Fig. A and B). On the left there was a continuous appearence of the middle ear ossicles. During surgery, the isolated fracture of the right malleus handle was visualised and an ossiculoplasty was performed using a hydroxylapatite bone cement (OtoMimix®, Biomet, Jacksonville, Florida) (Fig. C). Postoperatively, average pure-tone audiometry of air condition improved to 30 dB, and maximum air-bone gap improved to 35 dB at 500 Hz.

Highlights

  • A absent ipsilateral stapedial reflex in response to a broad-band stimulus

  • High resolution computed tomography (CT) imaging of the temporal bone was performed by a high-definition CT system (Discovery CT750 HD®, GE, Hounslow, England)

  • On the left there was a continuous appearence of the middle ear ossicles

Read more

Summary

Introduction

Tympanometry showed increased compliance in the right ear and an absent ipsilateral stapedial reflex in response to a broad-band stimulus. High resolution computed tomography (CT) imaging of the temporal bone was performed by a high-definition CT system (Discovery CT750 HD®, GE, Hounslow, England).

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.