Abstract

This study describes a unique, film-recorded computed tomography (CT) system and its use in studying contrast flow between anatomic compartments of the rat kidney. The CT apparatus, composed of a microfocal spot tube, rotating animal carrier, film-cassette translator, and control electronics, was used to expose "sinograms" of 3:1 magnification through the kidneys of normal rats prior to and 2, 15, 30, 60, and 120 minutes after intravenous contrast injection. Microdensitometry and computer reconstruction resulted in CT images representing 1-mm thick coronal sections with lateral resolution of 150 micron. With this novel technique of ultrahigh-resolution CT, temporal alterations in absorption coefficient of cortical and medullary nephrographic components were depicted for contrast flow study in our small animal model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.