Abstract
As part of a development programme for a high-intensity laser-plasma X-ray source, experiments have been carried out using a high repetition rate excimer laser (up to 100 Hz; 249 nm, 300 mJ). Remedies are given to problems inherent to operating this type of source at high repetition rates. The combined remedies eliminate the target debris problem. X-ray mask structures down to 0.5 μm have been imaged. After implementation of tested upgrades, this source will enable exposures within ten seconds per stepfield.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.