Abstract

To develop a method for determining the parameters of the final equation of state (EOS) of detonation products of aluminized explosives, an explosion quasi-static pressure measurement system in closed containers with a large mass-to-volume ratio is developed. The influence of domestic and foreign typical charge piezoelectric pressure sensors, sensor buffer adjustment structures, container tightness, grounding operation, weather, and other factors on the long-time measurement of high quasi-static pressure are comparatively studied. The test methods and conditions for obtaining standard quasi-static pressure-time curves are clarified. The influence of the mass of different aluminized explosives on the static pressure is obtained. The result shows that the foreign 113B03 type sensor is more suitable for measuring quasi-static pressure with a leakage effect in a humid environment. An appropriate sensor buffer adjustment structure and reliable grounding operation can significantly reduce the high-frequency oscillation of the signal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.