Abstract

This paper presents new experimental results on the separation of an o -dichlorobenzene/ p -dichlorobenzene mixture in a continuous moving crystal bed crystallization column under the top-fed operation mode. Local concentration distributions of the binary eutectic mixture were investigated as a function of the feed composition, reflux ratio, crystal bed height, and internal stirring speed. It is demonstrated that the key factor that is decisive to the separation capability of column crystallization is the reflux ratio. The experiments showed that product purities can easily exceed 99.0% over a wide range of feed compositions, 68–94 wt%, reflux ratios, 1.0–4.7, and crystal bed heights, 200–900 mm within a column of 50 cm i.d.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.