Abstract
Methods for the determination and confirmation of N-nitrosodiethanolamine (NDELA) in cosmetic products were developed. The NDELA fraction was isolated from a cosmetic product by a series of solvent extractions which were designed to concentrate the NDELA and remove ingredients deleterious to the analytical system. The isolated fraction was then analyzed for NDELA using a high pressure liquid chromatograph (HPLC) interfaced with a thermal energy analyzer (TEA). The compound was measured by comparison of detector response with those of known standards. NDELA was verified by gas chromatography-mass spectrometry of the silyl derivative after preliminary cleanup of the sample by gradient elution HPLC on a Partisil 10 PAC column. The limit of detection of NDELA by TEA is 2-3 ng, which corresponds to 20-30 ppb in the cosmetic product. Analysis of an emulsion cream and a hair grooming gel spiked at 3 and 4 ng concentration levels, respectively, yielded recoveries ranging from 71 to 103% (average 88%).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.