Abstract
Vitamin D3 was determined in commercially fortified instant nonfat dried milk by using normal phase high pressure liquid chromatography (HPLC). The sample was extracted with dichloromethane with sodium phosphate tribasic solution added. The sample was cleaned up by using a Sep-Pak silica cartridge and then a microparticulate column containing 10 micrometer Partisil-10 PAC packing material. The final analysis was performed by using a normal phase HPLC system with 10 micrometer LiChrosorb NH2 column. Recovery of vitamin D3 at levels as low as 10000 IU/kg was 97.7% with a standard deviation of 3.9%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.