Abstract
A high-pressure liquid chromatographic assay was developed for the quantitative analysis of a new cephalosporin, BMY-28142, in plasma and urine. The plasma method involved protein precipitation with acetonitrile and trichloroacetic acid followed by extraction of the acetonitrile into dichloromethane. After centrifugation, the organic phase was discarded, the aqueous solution was injected into a reverse-phase column, and peaks were detected at 280 nm. The urine method involved dilution of a urine sample with sodium acetate buffer (pH 4.25) and direct injection into the high-pressure liquid chromatography system. The assay validation data indicate that the assays for BMY-28142 in plasma and urine were specific, accurate, and reproducible. The analytical methods were applied to the determination of protein binding in human serum and to a pharmacokinetic study in rats. The results of the protein-binding study indicated that BMY-28142 was 16.3% bound to human serum proteins. In the pharmacokinetic study in rats, the maximum level in plasma of 38.7 micrograms/ml was achieved at 2.33 h after administration of a subcutaneous dose of 100 mg/kg. The levels in the plasma then declined with an elimination half-life of about 0.56 h. The mean values for the steady-state volume of distribution and total body clearance were 0.46 liters/kg and 11.9 ml/min per kg, respectively. The 0- to 24-h excretion of intact BMY-28142 in urine accounted for 88.6% of the dose.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.