Abstract
A new high-precision, cost-effective cutting system, able to produce thin (20–30 μm) sections of oral tissues, containing dental implants, is presented. With this system the authors have been able to obtain, in a reproducible and consistent way, thin slides containing biomaterials and biological tissues. Very high cellular detail was possible, even at high magnifications (× 1200). Histochemical reactions (e.g. acid and alkaline phosphatases) have also been obtained in a reproducible way, without sputter ground staining. The time involved in specimen cutting was significantly reduced, and about five slides per specimen were obtained with minimal loss of tissue. In almost all cases it has been possible to eliminate the grinding process with its inherent problems, such as formation of ledging at the bone-titanium interface. With this system it was also possible to obtain thin slides of soft tissue lesions (i.e. benign mucous membrane pemphigoid).
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.