Abstract
The clinical performance of high-power, short-duration (HPSD) pulmonary vein isolation (PVI) with the novel flexible tip TactiFlex™ (TFSE) catheter, as compared to standard-power, long-duration (SPLD) PVI using the TactiCath™ (TCSE) catheter among patients undergoing catheter ablation (CA) of atrial fibrillation (AF) is currently unknown. We conducted a prospective, observational, single-centre study including 40 consecutive patients undergoing PVI for paroxysmal/persistent AF, using HPSD ablation with the novel TFSE catheter (HPSD/TFSE group). Based on propensity score-matching, forty patients undergoing SPLD PVI with the TCSE catheter were identified (SPLD/TCSE group). In the HPSD/TFSE group, RF lesions were performed by delivering 40-50 W for 10-20s, while in the SPLD/TCSE group, RF power was 30-35 W, targeting a lesion size index (LSI) of 4.0-5.5. The co-primary study outcomes were time required to complete PVI and first pass isolation (FPI). PVI was achieved in 100% of patients in both groups, and no major adverse events were observed. Remarkably, PVI time was shorter in the HPSD/TFSE, compared to the SPLD/TCSE group(9 [7-9] min vs. 50 [37-54] min; p < 0.001), while FPI rate was non-significantly higher in the former group(91% [146/160] vs 83% [134/160]; p = 0.063). Shorter procedural (108 [91-120] min vs. 173 [139-187] min, p < 0.001), total RF (9 [7-11] min vs. 43 [32-53] min, p < 0.001), fluoroscopy times(15 [10-19] min vs. 18 [13-26] min, p = 0.014), and lower DAP (1461 [860-2181] vs. 7200 [3400-20,800], p < 0.001) were recorded in the HPSD/TFSE group. A higher average impedance drop was obtained with HPSD/TFSE CA(17[17-18]Ω vs. 16 [15-17] Ω, p < 0.001). In our initial clinical experience, HPSD PVI with the TFSE catheter proved faster than SPLD PVI with the TCSE catheter, at least equally effective in terms of FPI, and it was associated with greater impedance drop.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Interventional Cardiac Electrophysiology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.