Glow discharge detector (GDD) composed of a commercial miniature neon tube is utilized for direct detection of high-power millimeter waves. The detector was exposed directly to 95-GHz high power emitted from a gyrotron and the detector readings were recorded as a function of the incident power. The response of the GDD was examined for ~35-dB range. A linear regime was observed followed by a saturation regime. The detection was done without an amplifying stage as done for low power detection. The detector handling of high power without damage was experimentally demonstrated, even when exposed directly to high power. A dependence of the detector rise time on the measured power was observed. This detector can be used in a diagnostic setup of high power devices such as gyrotrons and free electron lasers. Since the cost of such detector is approximately three orders of magnitude less than a commercial W-band crystal detector, an array of detectors can be made for spatial analysis of a high power device output.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.