Abstract

A rapid, simple, stability-indicating assay procedure for otilonium bromide, a smooth muscle relaxant agent, and diazepam in composite tablet analysis was developed with high-performance liquid chromatography. The tablet matrix was dissolved with water, and drugs were extracted with acetonitrile containing an internal standard. An aliquot was centrifuged and chromatographed on a 5μm, reversed- phase column with 0.5M sodium acetate trihydrate buffer containing 5mM 1-heptanesulfonic acid monohydrate sodium salt:methanol (30:70; v/v; adjusted to pH 6.0 with glacial acetic acid) as the mobile phase. The selectivity of the chromatographic system was demonstrated by resolving both compounds from various potential degradation products of each compound. The method is linear, quantitative, and reproducible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.