Abstract

A sensitive, selective and simple post-column detection method for the determination of propylthiouracil (PTU) based on its sensitizing induction on iodine–azide reaction and the combination technique of high-performance liquid chromatography has been presented. The analysis was conducted in the optimum conditions for iodine–azide detection system and HPLC separation. The linear range, the lower limit of detection and quantification for PTU in urine were established at the levels of 0.4–1.0 nmol/ml urine, 0.3 nmol/ml urine and 0.4 nmol/ml urine, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.