Abstract

Batch SPM systems do not meet the current clean specification/requirements below 28nm. Single wafer SPM systems use a high volume of chemistry which runs to drain, while meeting the cleaning specifications below 28nm. The work in this paper describe the use of a batch SPM system and a single wafer clean in an integrated system, Ultra-C Tahoe which results in meeting the technical specification and using less that 80% of the SPM chemistry used in single wafer systems. The data collected shows this new system meet the specifications, whilst saving more than 80%of SPM chemistry.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call