Abstract

High-energy radiation detectors with a good imaging resolution, fast response, and high sensitivity are desired to operate at a high electric field. However, strong ion migration triggered by electrochemical reactions at the interface between a high-potential electrode and an organic-inorganic hybrid perovskite limits the stability of radiation detectors under a high electric field. Herein, we demonstrate that such ion migration could be effectively suppressed in devices with a Ti cathode, even at a high electric field of 50 V mm-1, through time-of-flight secondary-ion mass spectrometry. X-ray photoelectron spectroscopy illustrates that Ti-N bonds formed at the interface of MAPbBr3 perovskite single crystals/Ti electrode effectively inhibit the electrochemical reaction in organic-inorganic hybrid perovskite devices and ultimately improve the operating stability under a high electric field. The device with a Ti electrode reaches a high sensitivity of 96 ± 1 mC Gyair-1 cm-2 and a low detection limit of 2.8 ± 0.3 nGy s-1 under hard X-ray energy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call