Abstract

A novel pre-cyclone jet singlet oxygen generator (PJSOG) has been the focus of research for recent years. In this paper, the high liquid-gas ratio separation performances of PJSOG have been studied by means of theoretical and experimental analysis. The liquid excess of the critical mass concentration portion can be easily captured due to initial BHP particles swirling momentum for a specific designed structure. At high flow speeds, the vacuum mixed Cl2/He with a weak entrainment capability insures high separation efficiency. Large quantities of experiments have verified that the new PJSOG do have the excellent operation performances of high separation efficiency, high O2 (1Δ) output coefficient, high utilization coefficient of Cl2 and excellent operating flexibility and stability. All the results show that the new PJSOG is a feasible and promising technology in singlet oxygen generation cases.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.