We tested the ability of tracheostomized, high-level quadriplegics to detect changes in ventilator-delivered tidal volume. Single breaths larger or smaller than control breaths were delivered, and the subjects indicated which breath was altered in a forced-choice procedure that minimizes the effect of subject bias. Quadriplegic patients detected changes in tidal volume of as little as 100 ml. Their ability to detect changes was comparable to that of a group of normal subjects similarly tested. These quadriplegic patients had little or no somatic sensation below the neck, and airways above the tracheostomy were not exposed to the stimulus. The quadriplegics consistently and emphatically reported that the sensation used in volume discrimination arose within the chest.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.