Abstract

High-level dynamic testing of a prototypic insulated small bore diameter pipe system is described. The pipe system was supported by a minimum number of supports, with several combinations of supports and support locations tested. Load input consisted of a dynamic multifrequency time history and sinusoidal loading at increasing acceleration levels until gross deformation of the system occurred. Very high level pipe damping was exhibited when plastic response occurred. Post-test analyses were performed to assess the structural loading and response of the pipe system under the dynamic load input. Several elastic and elasto-plastic analysis failure prediction methods were used, along with simplified inelastic analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.