Abstract

We intensified our screening protocol for the presence of pseudotumours in a consecutive series of patients with a hip resurfacing arthroplasty (HRA), to establish whether we should be alert to the presence of 'silent' pseudotumours. Patients categorised with high risk (11 hips) and low risk (10 hips) for pseudotumour development and a control group (23 hips) were screened with metal artefact reduction sequence (MARS) magnetic resonance imaging (MRI). The Anderson classification to grade any metal-on-metal (MoM) disease present on MARS-MRI images was used. In 15 out of 44 MRI scans pseudotumours were observed (34.1%), of which six were graded with mild (13.6%), eight with moderate (18.2%) and one with severe MoM disease (2.3%). Twelve pseudotumours were present in asymptomatic patients (27.3%). Metal ion levels were normal in 80% of the MARS-MRI screened patients. As a consequence of our intensified screening protocol, one patient was revised for pseudotumour formation and another patient was scheduled for revision. Silent pseudotumours were observed in all three groups. Before our intensified screening protocol was initiated, no pseudotumours were encountered in our cohort of 289 HRAs. We concluded that clinical outcomes and plain radiographs for screening MoM patients underestimates the presence of pseudotumours in MoM patients. The true clinical relevance of these pseudotumours is still unclear.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.