Abstract

The ITER neutral beam duct liner is located within the tokamak VV port extension and is mounted on the VV port extension flange. The duct liner is made from CuCrZr copper alloy and is actively cooled through deep-drilled channels. A number of thermocouples should be installed on the neutral beam duct liner in order to provide the ability to detect temperature excursions on the surface of the duct liner. Twenty thermocouples have been installed on the neutral beam duct liner full scale mock-up, and a high heat flux test has been performed at the KoHLT-EB test facility, in order to simulate temperature detection in the neutral beam duct liner during ITER operation. For each thermocouple, the fixation method has been verified by high heat flux test with uniform electron beam profile, and the temperature behavior of the neutral beam duct liner has been successfully simulated by Gaussian electron beam profile.