Abstract

AbstractDust particles originally generated by two steelmaking processes were dispersed in an air stream and passed through a pilot‐scale high gradient magnetic filter. In accordance with theoretical predictions, the experimental results showed that collection was improved by increasing the depth or density of the steel wool filter, increasing the applied magnetic field, or decreasing the filtration velocity. Collection efficiency increased with particle size up to about 2 μm, above which the efficiency tapered off, apparently due to reentrainment effects. Collection efficiencies of greater than 99% were obtained, indicating that high gradient magnetic filtration may be a practical method of controlling particulate emission from processes in the iron and steel industry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.