Abstract

Movements of the liver caused by spontaneous breathing (during sedation or local anaesthesia) or by ventilation during anaesthesia are a source of concern in CT-guided procedures because of the limited spatial and contrast resolution of unenhanced imaging, artifacts caused by the probes and the relatively low temporal resolution of the fluoroscopy mode. During CT-guided radiofrequency ablation (RFA), it is essential that the lesion can be visualized optimally and that the ablation probe is positioned accurately to avoid non-target injuries. We therefore used high-frequency jet ventilation and general anaesthesia to minimize ventilation-related liver movement and provide optimal conditions for a patient undergoing RFA of hepatic metastases. The technical and anaesthetic considerations are discussed, and a specific limitation of transcutaneous PCO(2) measurement during activation of the ablation is reported for the first time.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.