Abstract
In the high-frequency (HF) signal injection based position sensorless permanent magnet synchronous motor (PMSM) drives, there is an estimated position error caused by the cross-saturation effect and other factors. In order to suppress the position error, an HF injection angle self-adjustment based online suppression method is proposed in this letter. By tracking the sign of the increment of the absolute back electromotive force in the estimated frame, the criterion of the HF injection angle self-adjustment can be determined online and the position error can be mitigated effectively. This method can avoid the offline measurement or the variation of the operating state, which has a satisfactory suppression effect for the position error under different operating conditions. The effectiveness is verified by experiments on a 2.2-kW PMSM drive platform.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.