Abstract

Planning an automatic detection system of the air tightness of medicine box is very necessary for growing demand for storage of pharmaceutical products. In this study, the high-fidelity CFD study is performed for the air tightness of the medicine box, using the LBM algorithm. The high-fidelity results indicate that after about 5.24 s, the stable value of the average static pressure of the ring cavity remains at about -9414 Pa. The slit flow in the early stage of micro-leakage is very complicated, especially for the initial stage. The location of the micro-leakage is concentrated in the directions of 1 o’clock, 4 o’clock, 7 o’clock and 11 o’clock along such edge of the end cap, therefore, the sealed end cover needs to be further improved. Additionally, the idea of this research work can provide a good basis and reference for the subsequent series of related airtightness studies.