During the survey of substandard medicines in Cambodia in 2007, it was found that more than 90% of 500-mg amoxicillin (AMPC) capsules failed the United States Pharmacopeia (USP) 30 TEST 1 dissolution test. In the USP, several monographs provide multiple methods for performing the dissolution test. By using the 500-mg AMPC capsule as an example, we aimed to identify the problems and implications of the USP methods adopted for the dissolution test as a global standard. All AMPC samples were collected from the Cambodian market in 2007. For the quantitative test, we referred to USP 30. We performed the USP 28 and USP 30 TEST 2 dissolution tests and compared these results with those of the USP 30 TEST 1. All 500-mg AMPC capsules used for the comparison passed the quantitative test. Samples that passed the USP 28 and USP 30 TEST 2 dissolution tests were identical, and the pass rate was 97.1% (34/35), whereas the pass rate with the USP 30 TEST 1 was 8.6% (3/35). The difference in the dissolution results between the three methods was significant (P<0.0001). This study revealed that many users would select the most stringent method when multiple methods exist in the USP. This may lead to a high failure rate of the tests. Because USP is a global standard, we recommend that it take into consideration the developing countries and create a more detailed user-friendly manual for selection for appropriate methods.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.