Abstract

The negatively charged nitrogen vacancy (NV-) center ensembles in diamond have been demonstrated to be a promising platform for quantum metrology, but the poor fluorescence collection efficiency of a microscope objective limits the sensitivity of the NV- based sensors. Here we present a method for increasing the collected fluorescence intensity with a total internal reflection (TIR) lens. The detected fluorescence intensity is increased by approximately a factor of 56 compared with detection using a microscope objective with NA = 0.55, leading to a collection efficiency of 47.7% ± 3.1%. The signal-to-noise ratio is improved by a factor of 7.6 using the TIR lens. The proposed method is of great significance for collecting fluorescence from NV- centers in a large volume and can be used in weak fluorescence detection systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.