Abstract

The efficient and precise extraction of target particles is a crucial prerequisite for achieving accurate detection and analysis in microfluidic cell analysis. In this study, a symmetrical contraction-expansion microchannel with sheath flow was designed, aiming to extract target larger particles from particles of different sizes within the channel. This paper conducted numerical simulations to investigate the three-dimensional migration mechanisms of particles and performed experimental studies to examine the separation performance of particles with different sizes under varying flow rate ratios and different numbers of contraction-expansion structures. The experimental results indicate that at moderate sample flow rates and higher flow rate ratios, microchannels with fewer contraction-expansion structures are likely to achieve better performance in extracting target particles compared to microchannels with a greater number of these structures. Our work advances the application of viscoelastic contraction-expansion microchannels in particle separation. This device is easy to set up in parallel and significantly enhances throughput, providing an accurate and efficient solution for future particle separation applications.