Abstract
We report on the pulse contrast-ratio characterization of a few-cycle 0.2 TW optical parametric chirped pulse amplifier system operating at 20 Hz. A specially designed third-order correlator was used to characterize and optimize the contrast of the system. We demonstrate that the pulse contrast depends much more on the temporal overlap between the pump and the seed pulse than the shape of the amplified spectrum. The best amplified pulse contrast-ratio was 10-4 at Δt=±25 ps and >10-9 at Δt=±150 ps delays.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.